Altelix 32x24x12 Vented Fiberglass Weatherproof NEMA Enclosure with 120 VAC Outlets & Dual 85°F Turn-On Cooling Fans

Altelix 32x24x12 Vented Fiberglass Weatherproof NEMA Enclosure with 120 VAC Outlets & Dual 85°F Turn-On Cooling Fans

Availability: Ships in 1 - 2 days
SKU: ALT.NFC322412VFA185

Product Information

The Altelix NFC322412VFA1-85 Vented Fan Cooled Weatherproof NEMA Enclosure with 120VAC Power and Equipment Plate is ideal for protecting equipment from harsh environments and tampering. Equipment designed for indoor use can now be located outside.

Construction and Features
This rugged enclosure is molded from durable and UV resistant fiberglass reinforced polyester (FRP). The door is fully gasketed making this enclosure suitable for use indoors or outdoors. The lockable door features reinforced hinges and dual quarter-turn latches to secure the enclosure and is locked and unlocked using the included removable keys. A drip rail over the door provides additional protection against water dripping into the cabinet while the enclosure is wet.

Bonus Aluminum Bottle Opener Key
This enclosure now includes our HN-0008 Aluminum Bottle Opener Key. A $7.99 value, this heavy duty aluminum door locking key easily attaches to most key chains. And it makes a great bottle opener too!

Power
This configuration consists of the fiberglass NEMA enclosure with hinged lid and a equipment mounting plate with two pre-wired duplex 120VAC power outlets (4 outlets total). The outlet box is easily removable to facilitate wiring to an external power source.

Dual 85°F Turn-On Cooling Fans
The NFC322412VFA1-85 is designed for applications which require the cooling fans to turn on at a lower temperature then our standard fan cooled enclosures. These low noise, high airflow fans turn on when the internal temperature reaches 85°F (30°C) and turns off when it drops to 59°F (15°C). The fans are wired internally so it does not require the use of the AC outlets leaving them available for internal equipment use. The dual 4″ vents feature rain shrouds on the front door keep rain water from entering the enclosure, and the internal screens are removable for cleaning.

Galvanized Steel Equipment Mounting Plate
This configuration consists of the fiberglass NEMA enclosure with hinged lid and a 16 Gauge (1.5mm thick) galvanized steel plate for mounting and securing equipment. The enclosure and plate can be drilled and modified by the installer to suit unique site requirements.

Integral T-Slot Nut Mounting System
Molded into the interior of the enclosure is a versatile mounting system can be used to mount different size and types of equipment mounting plates as well as DIN rails without modifying the enclosure. Designed for use with T-Slot Nuts, they run the full length of the enclosure from top to bottom. This mounting system provides the flexibility needed when configuring the enclosure for specific user requirements. For recommended T-Slot Nut size, see specification sheet in the Downloads section.

Mounting
Four mounting feet are included so that the enclosure can be securely mounted to a wall or other structure. Two optional flange and pole mounting kits are available, painted steel (model NMKS-600-08) and stainless steel (model NMKX-600-08).

Optional Lockable Latches
For additional protection of internal equipment installed, three lockable latches are available. The HN-0005 is a keyed lock set which includes two keys. Similar to the HN-0005, the HN-0001 has an interlock feature that traps the key when it is in the unlocked position. The HN-0006 allows the enclosure to be securely locked via use of a padlock (not included). All of these optional lockable latches are direct replacements for the standard quarter-turn latches that come pre-installed in the enclosures.

Customization
This enclosure is one of many standard models available. Our lineup includes enclosures specifically tailored for WiFi equipment, DIN Mount Industrial Controls, POTS Telephones, IP Phones, Device Charging Stations, Security & Safety Equipment, Building & Home Automation and More.

We offer numerous standard models and options including equipment mounting plates, DIN rails, AC or DC power, air vents, cooling fans and heaters and more. We also offer full customization, engineering and on-site CNC machining of enclosures and associated equipment, all with quick turnaround time. Please contact us with your unique requirements.


Features

  • (2) 4″ Vents with Rain Shields and Screens
  • (2) Thermostat Controlled 85°F Turn-On Cooling Fans
  • Heavy Duty Fiberglass Reinforced Polyester (FRP) Construction
  • Includes Blank Galvanized Steel Equipment Mounting Plate
  • (4) 120VAC Outlets
  • Dual Quarter-Turn Door Latches
  • Bonus Aluminum Bottle Opener Key Now Included!
  • (4) Mounting Feet Included
  • NEMA Type 3R, 3RX / IP24 Rated
  • Optional Lockable Latch Sets Available
  • Proudly Made Here in the USA with Global Materials

Applications

  • Indoor / Outdoor WiFi Equipment
  • SCADA Remote Terminal Unit
  • Security and Surveillance Systems
  • Outdoor use of Indoor Equipment
  • Protection of Equipment from Theft or Damage
  • Concealment of Electronic Equipment

Material Fiberglass Reinforced Polyester
Color Light Gray
Voltage 120VAC
Max Load 15A @ 120VAC
Cooling Fans Turn-On Temperature 85°F (30°C)
Cooling Fans Turn-Off Temperature 59°F (15°C)
Outer Dimensions 31.5 x 23.6 x 11.8 Inches
(802 x 600 x 300 mm)
Inner Dimensions 29.9 x 22.1 x 8.9 Inches
(761 x 561 x 226 mm)
Equipment Plate Material 16 Gauge Galvanized Steel
Equipment Plate Dimensions 21.3 x 29.5 In. (540 x 749 mm)
Weight 40.6 lbs. (18.4 kg)
Ratings NEMA Type 3R, 3RX / IP24

 

NEMA Ratings and IP Equivalency Chart
This chart provides the different NEMA ratings and their definitions as well as the IP equivalents and definitions.

Additional information

Weight 42 lbs
Dimensions 34 × 25 × 13 in

PVC-coated Products; PVC-coated Wires and Cables

WARNING: This product may expose you to chemicals including DINP and/or DEHP, which are known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov or our information page: California Proposition 65 Info.